Home
 


Cylindrical Fuses
Littlefuse fast-acting (gL-gG) fuses are used for the protection of cables against short circuits. Time-lag(aM) fuses are used for projection of motors.

SPECIFICATIONS

Standards: IEC 269-2.1
Example part number: CY22X58G50

Size Current Range Voltage AC Interruption Rating
10 x 38 mm 5-32A 500V 120KA
14 x 51 mm 2-50A 500V 80KA
22 x 58 mm 16-100A 500V 80KA

  gL-gG aM
Amperage 10x38 14x51 22x58 10x38 14x51 22x58
0.5 CY10X38G.5 - - CY10x38M.5 - -
1 CY10X38G1 - - CY10x38M1 - -
2 CY10X38G2 CY14x51G2 - CY10x38M2 CY14x51M2 -
4 CY10X38G4 CY14x51G4 - CY10x38M4 CY14x51M4 -
6 CY10X38G6 CY14x51G6 - CY10x38M6 CY14x51M6 -
8 CY10X38G8 CY14x51G8 - CY10x38M8 CY14x51M8 -
10 CY10X38G10 CY14x51G10 - CY10x38M10 CY14x51M10 -
12 CY10X38G12 CY14x51G12 - CY10x38M12 CY14x51M12 -
16 CY10X38G16 CY14x51G16 CY22x58G16 CY10x38M16 CY14x51M16 CY22x58M16
20 CY10X38G20 CY14x51G20 CY22x58G20 CY10x38M20 CY14x51M20 CY22x58M20
25 CY10X38G25 CY14x51G25 CY22x58G25 CY10x38M25 CY14x51M25 CY22x58M25
32 CY10X38G32 CY14x51G32 CY22x58G32 CY10x38M32 CY14x51M32 CY22x58M32
40 - CY14x51G40 CY22x58G40 - CY14x51M40 CY22x58M40
50 - CY14x51G50 CY22x58G50 - CY14x51M50 CY22x58M50
63 - - CY22x58G63 - - CY22x58M63
80 - - CY22x58G80 - - CY22x58M80
100 - - CY22x58G100 - CY22x58M100
Dimensions A 10 14 22 10 14 22
(mm) B 38 51 58 38 57 58

FUSEHOLDERS

Part No. Size Amp.Rating VoltageTerminal Type
CYH10381 10x38 32A 690V Pressure Plate
CYH10382 10x38 32A 690V Pressure Plate
CYH10383 10x38 32A 690V Pressure Plate
CYH1038111D 10x38 32A 690V Pressure Plate
CYH14511 14x51 50A 690V Pressure Plate
CYH14512 14x51 50A 690V Pressure Plate
CYH14513 14x51 50A 690V Pressure Plate
CYH22581 22x58 125A 690V Pressure Plate
CYH22582 22x58 125A 690V Pressure Plate
CYH22583 22x58 125A 690V Pressure Plate
*Indicating NOTE: All fuseholders are DIN mountable.

ASSEMBLY PINS Assembly pins used for CHY10x38 fuseholders.

Part No. Size No. of Poles
CYHP2 10x38 2
CYHP3 10x38 3
CYHP4 10x38 4
Contact factory for dimentional informations.


215 Series (Type T)
5 x 20 MM SLO-BLO FUSE
Time-delay protection of electronic equipment and appliances when fuses to International Standards are required. Replacement fuses for foreign equipment.

Voltage Rating: 250V AC
 
Ampere Ratings:
.200 .400 .800 1.6 3.16 6.3
.250 .500 1 2 4 8*
.315 .630 1.25 2.5 5 10*
*Available but not included in International Standards.

Interrupting Capacity : 1500A
Approvals : Recognized under the Components Program of UL, SEMKO, VDE and BSI approved through 6.3A. MITI approved 1 - 5A.
Design Standards : I.E.C.127, Sheet V.C.E.E. Pub. 4, Sheet III, DIN 41662. BS 4265, Sheet III, SEMKO 24, Normblad III, C93-430
Feuille de Norme III. Dimensions: 5mm x 20 mm (.2 x .79 in.)
Example part number(series & amperage): 215315





216 Series (Type F)
5 x 20MM FAST-ACTING FUSE
Fast-acting protection of electronic equipment and appliances when fuses to International Standards are required. Replacement fuse for foreign equipment.

Voltage Rating:250V AC

Ampere Ratings:
.050 .125 .315 .800 2 5
.063 .160 .400 1 2.5 6.3
.080 .200 .500 1.25 3.15 8*
.100 .250 .630 1.6 4 10*
*Available but not included in International Standards.

Interrupting Capacity : 1500A
Approvals : Recognized under the Components Program of UL, SEMKO: .050 - 6.3A
Design Standards : I.E.C. 127, Sheet 1. C.E.E. Pub, 4 Sheet 1. DIN 41660, BS4265, Sheet 1, SEMKO 24, Normblad 1.
Dimentions : 5mm x 20mm (.2 x .79 in.)
Example part number (series & amperage): 216.200



217 Series (Type F)
5 x 20MM FAST-ACTING FUSE
Fast-acting protection of electronic equipment and appliances when fuses to International Standards are required. Replacement fuse for foreign equipment.

Voltage Rating :250V AC
Ampere Ratings :
.032 .100 .315 .800 2 5
.040 .125 .400 1 2.5 6.3
.050 .160 .500 1.25 3.15 8*
.063 .200 .630 1.6 4 10*
.080 .250
*Available but not include in International Standards.

Interrupting Capacity : 35A or 10x rated current, whichever is greater.
Approvals : Recognized under the Components Program of UL, SEMKO and BSI approved through 6.3A
Design Standards : I.E.C. 127, Sheet 11. C.E.E. Pub, 4 Sheet 11. DIN 41660, BS4265, Sheet 1, SEMKO 24, Normblad 1.
Dimentions : 5mm x 20mm (.2 x .79 in.)
Example part number (series & amperage): 217.050



218 Series (Type F)
5 x 20MM SLO-BLO FUSE
Time delay protection of electronic equipment and appliances when fuses to International Standards are required. Replacement fuse for foreign equipment.

Voltage Rating :250V AC
Ampere Ratings :
.032 .100 .315 .800 2 5
.040 .125 .400 1 2.5 6.3
.050 .160 .500 1.25 3.15 8*
.063 .200 .630 1.6 4 10*
.080 .250
*Available but not include in International Standards.

Interrupting Capacity : 35A or 10x rated current, whichever is greater.
Approvals : Recognized under the Components Program of UL, SEMKO and BSI approved through 6.3A
Design Standards : I.E.C. 127, Sheet 111. C.E.E. Pub, 4 Sheet 111. DIN 41660, BS4265, Sheet 111, SEMKO 24, Normblad 111 C93-430. Feuile de Norme 111.
Dimentions : 5mm x 20mm (.2 x .79 in.)
Example part number (series & amperage): 217.050